Position Resolution
A particle’s vertical position of intersection at the TOF can be measured.
- Two tubes per scintillator.
- Use the time difference between tubes.
- Use the ratio of the energy deposited between tubes.
Tests have shown that the position can be determined with a resolution of…
- 1cm using the time difference.
- 4cm using the energy ratio.